Research map: Radiological review of interval breast cancers following screening with DBT + DM or DM: results from MAITA project randomized trials

Back to the article

Papers in this map

  1. Screening for Breast Cancer · US Preventive Services Task Force · 2024 · 460 citations · Cited by this paper
  2. Diffusion tensor imaging with 3D high-resolution MRI of lumbosacral nerve roots in lumbar disc herniation with radiculopathy and its clinical correlations: a prospective study · 2026 · Related
  3. Breast Cancer Screening and Diagnosis: A Synopsis of the European Breast Guidelines · Holger Jens Schünemann · 2019 · 295 citations · Cited by this paper
  4. Radiologic exposomics: imaging the environmental imprint on cancer for precision oncology · 2026 · Related
  5. Breast Cancer Screening Using Tomosynthesis or Mammography: A Meta-analysis of Cancer Detection and Recall · M. Luke Marinovich · 2018 · 250 citations · Cited by this paper
  6. Can we use MRI for timing estimation of rotator cuff tears? · 2026 · Related
  7. Digital Mammography versus Digital Mammography Plus Tomosynthesis in Breast Cancer Screening: The Oslo Tomosynthesis Screening Trial · Per Skaane · 2019 · 172 citations · Cited by this paper
  8. High-dose-rate vaginal brachytherapy for treatment of recurrent high-grade vaginal intraepithelial neoplasia · 2026 · Related
  9. The current detectability of breast cancer in a mammographic screening program. A review of the previous mammograms of interval and screen-detected cancers · Jos A.A.M. van Dijck · 1993 · 155 citations · Cited by this paper
  10. Ethanol ablation of cystic thyroid nodules: institutional experience with one year follow-up · 2026 · Related
  11. Digital Mammography versus Digital Mammography Plus Tomosynthesis for Breast Cancer Screening: The Reggio Emilia Tomosynthesis Randomized Trial · Pierpaolo Pattacini · 2018 · 133 citations · Cited by this paper
  12. Environmental impact of percutaneous core-needle breast biopsy in 101 Senonetwork Italian breast cancer centers · 2026 · Related
  13. Two-view digital breast tomosynthesis versus digital mammography in a population-based breast cancer screening programme (To-Be): a randomised, controlled trial · Solveig S. H. Hofvind · 2019 · 112 citations · Cited by this paper
  14. Image-guided adaptive interventional radiotherapy (modern brachytherapy) boost for vaginal recurrences · 2026 · Related
  15. Breast Cancer: Missed Interval and Screening-detected Cancer at Full-Field Digital Mammography and Screen-Film Mammography— Results from a Retrospective Review · Solveig Roth Hoff · 2012 · 106 citations · Cited by this paper
  16. Abbreviated non-contrast magnetic resonance enterography for Crohn’s disease: a reliability study · 2026 · Related
  17. Digital breast tomosynthesis plus synthesised mammography versus digital screening mammography for the detection of invasive breast cancer (TOSYMA): a multicentre, open-label, randomised, controlled, superiority trial · Walter Heindel · 2022 · 105 citations · Cited by this paper
  18. CT imaging of thyroid cartilage invasion in glottic laryngeal cancer: correlation of traditional semiotics and texture analysis with histopathology · 2026 · Related
  19. Screening for Breast Cancer · Jillian T. Henderson · 2024 · 102 citations · Cited by this paper
  20. Safety and efficacy of Glubran-2® endovascular embolization in acute bleeding patients with coagulopathies: a multicenter experience · 2026 · Related
  21. Performance of Digital Breast Tomosynthesis, Synthetic Mammography, and Digital Mammography in Breast Cancer Screening: A Systematic Review and Meta-Analysis · Mostafa Alabousi · 2020 · 96 citations · Cited by this paper
  22. Monitoring Interval Cancers in Breast Screening Programmes: The East Anglian Experience · Nicholas Day · 1995 · 94 citations · Cited by this paper
  23. Radiological surveillance of interval breast cancers in screening programmes · Nehmat Houssami · 2006 · 81 citations · Cited by this paper
  24. Influence of Review Design on Percentages of Missed Interval Breast Cancers: Retrospective Study of Interval Cancers in a Population-based Screening Program · Solveig S. H. Hofvind · 2005 · 79 citations · Cited by this paper
  25. A Randomized Trial Comparing Breast Cancer Incidence and Interval Cancers after Tomosynthesis Plus Mammography versus Mammography Alone · Pierpaolo Pattacini · 2022 · 62 citations · Cited by this paper
  26. Missed Breast Cancer: Effects of Subconscious Bias and Lesion Characteristics · Leslie R. Lamb · 2020 · 61 citations · Cited by this paper
  27. Trial Design Based on Surrogate End Points--Application to Comparison of Different Breast Screening Frequencies · Nicholas E. Day · 1996 · 59 citations · Cited by this paper
  28. Breast Density and Breast Cancer Screening with Digital Breast Tomosynthesis: A TOSYMA Trial Subanalysis · Stefanie Weigel · 2022 · 56 citations · Cited by this paper
  29. Interval breast cancers in screening: The effect of mammography review method on classification · Stefano Ciatto · 2007 · 48 citations · Cited by this paper
  30. Tumor Characteristics and Molecular Subtypes in Breast Cancer Screening with Digital Breast Tomosynthesis: The Malmö Breast Tomosynthesis Screening Trial · Kristin Johnson · 2019 · 39 citations · Cited by this paper
  31. A randomised controlled trial of digital breast tomosynthesis vs digital mammography as primary screening tests: Screening results over subsequent episodes of the Proteus Donna study · Paola Armaroli · 2022 · 32 citations · Cited by this paper
  32. Interval breast cancer rates for digital breast tomosynthesis versus digital mammography population screening: An individual participant data meta-analysis · Nehmat Houssami · 2021 · 29 citations · Cited by this paper
  33. Mammographic features and screening outcome in a randomized controlled trial comparing digital breast tomosynthesis and digital mammography · HS Aase · 2021 · 16 citations · Cited by this paper
  34. Impact of the Introduction of Digital Mammography in an Organized Screening Program on the Recall and Detection Rate · Cinzia Campari · 2015 · 14 citations · Cited by this paper
  35. Interval breast cancers: Absolute and proportional incidence and blinded review in a community mammographic screening program · Luca Alessandro Carbonaro · 2013 · 10 citations · Cited by this paper
  36. Comparing accuracy of tomosynthesis plus digital mammography or synthetic 2D mammography in breast cancer screening: baseline results of the MAITA RCT consortium · Paolo Giorgi Rossi · 2024 · 10 citations · Cited by this paper
  37. Discordant and false-negative interpretations at digital breast tomosynthesis in the prospective Oslo Tomosynthesis Screening Trial (OTST) using independent double reading · Per Skaane · 2023 · 4 citations · Cited by this paper

Source: OpenAlex (CC0)