Research map: An Implantable Magnetohydrodynamic Pump for Generating Fluid Flow During Bone Fracture Healing

Back to the article

Papers in this map

  1. Neural Stimulation and Recording Electrodes · Stuart F. Cogan · 2008 · 2279 citations · Cited by this paper
  2. Developing A Portable Breath Sampling System For Rapid, Point-Of-Care Disease Detection · 2026 · Related
  3. A mechano-regulation model for tissue differentiation during fracture healing: analysis of gap size and loading · Damien Jerome Lacroix · 2002 · 690 citations · Cited by this paper
  4. Design Process and Engineering Evaluation of a Cost-Effective Traumatic Hemorrhage Control Simulator · 2025 · Related
  5. Delayed union and nonunions: Epidemiology, clinical issues, and financial aspects · David J. Hak · 2014 · 654 citations · Cited by this paper
  6. Steerable Sheaths That Turn Endoscopes into Robotic Platforms for Colon Interventions · 2026 · Related
  7. A model of safe levels for electrical stimulation · Robert V. Shannon · 1992 · 542 citations · Cited by this paper
  8. Priorities in Planning Pediatric Medical Device Countermeasures · 2026 · Related
  9. Theoretical and experimental study of MHD (magnetohydrodynamic) micropump · Jaesung Jang · 2000 · 487 citations · Cited by this paper
  10. Verification and Validation of an Autotuning Proportional–Integral–Derivative Controller for Spatially Confined Magnetic Particle Hyperthermia · 2025 · Related
  11. Restraint stress in biobehavioral research: Recent developments · Tatyana Buynitsky · 2009 · 433 citations · Cited by this paper
  12. A Decade of Food and Drug Administration Medical Device Authorizations (2015–2025): Pathway, Specialty, and Artificial Intelligence/Machine Learning Trends · 2026 · Related
  13. An AC magnetohydrodynamic micropump · Asuncion V. Lemoff · 2000 · 414 citations · Cited by this paper
  14. Evaluation of Pressure Sensing Modalities and Lumen Design Parameters for a Novel Multifunctional Neonatal Feeding and Vital Signs Monitoring Catheter · 2025 · Related
  15. Prevalence of long-bone non-unions · Christopher C. Tzioupis · 2007 · 379 citations · Cited by this paper
  16. Mechanical Properties and Engineering Analysis of Intramedullary Bone Fixation Nails Made From Fiber-Reinforced Composites: A Review · 2025 · Related
  17. Incidence, Costs and Predictors of Non-Union, Delayed Union and Mal-Union Following Long Bone Fracture · Christina L. Ekegren · 2018 · 316 citations · Cited by this paper
  18. Intramedullary Nailing of the Lower Extremity: Biomechanics and Biology · Matthew R. Bong · 2007 · 260 citations · Cited by this paper
  19. Strain Rate and Timing of Stimulation in Mechanical Modulation of Fracture Healing · Allen E. Goodship · 1998 · 236 citations · Cited by this paper
  20. Blood and interstitial flow in the hierarchical pore space architecture of bone tissue · Stephen C. Cowin · 2014 · 177 citations · Cited by this paper
  21. Review of magnetohydrodynamic pump applications · Osama M. Al-Habahbeh · 2016 · 169 citations · Cited by this paper
  22. Corroboration of mechanoregulatory algorithms for tissue differentiation during fracture healing: comparison with in vivo results · Hanna Isaksson · 2006 · 147 citations · Cited by this paper
  23. Effect sizes for nonparametric tests · Fernanda Fiel Peres · 2025 · 134 citations · Cited by this paper
  24. Early dynamization by reduced fixation stiffness does not improve fracture healing in a rat femoral osteotomy model · L. Claes · 2008 · 116 citations · Cited by this paper
  25. The Future of Bone Repair: Emerging Technologies and Biomaterials in Bone Regeneration · Julia Weronika Łuczak · 2024 · 107 citations · Cited by this paper
  26. Fracture healing in the elderly: A review · Bradley A. Foulke · 2016 · 101 citations · Cited by this paper
  27. Delayed Union and Nonunion: Current Concepts, Prevention, and Correction: A Review · Kristin M. Bowers · 2024 · 88 citations · Cited by this paper
  28. THE ILIZAROV METHOD IN NONUNION, MALUNION AND INFECTION OF FRACTURES · David Russell Marsh · 1997 · 84 citations · Cited by this paper
  29. Characterization of the electrical conductivity of bone and its correlation to osseous structure · Thomas Wyss · 2018 · 74 citations · Cited by this paper
  30. Modulation of fixation stiffness from flexible to stiff in a rat model of bone healing · Nicole Bartnikowski · 2016 · 61 citations · Cited by this paper
  31. Some practical applications of magnetohydrodynamic pumping · Champak Das · 2013 · 56 citations · Cited by this paper
  32. The Magnetohydrodynamic Effect and Its Associated Material Designs for Biomedical Applications: A State‐of‐the‐Art Review · T. S. Gregory · 2016 · 56 citations · Cited by this paper
  33. Risk factors and healthcare costs associated with long bone fracture non-union: a retrospective US claims database analysis · Mari F. Vanderkarr · 2023 · 51 citations · Cited by this paper
  34. Advancement in biomedical implant materials—a mini review · Ashish Daniel S. · 2024 · 49 citations · Cited by this paper
  35. Wireless Implantable Sensor for Noninvasive, Longitudinal Quantification of Axial Strain Across Rodent Long Bone Defects · Brett S. Klosterhoff · 2017 · 46 citations · Cited by this paper
  36. A finite difference model of load-induced fluid displacements within bone under mechanical loading · Roland Steck · 2000 · 45 citations · Cited by this paper
  37. Wireless sensor enables longitudinal monitoring of regenerative niche mechanics during rehabilitation that enhance bone repair · Brett S. Klosterhoff · 2020 · 44 citations · Cited by this paper
  38. Flow Analysis of Non-Newtonian Blood in a Magnetohydrodynamic Pump · Azadeh Shahidian · 2009 · 40 citations · Cited by this paper
  39. Mechanically-regulated bone repair · Tareq Anani · 2021 · 34 citations · Cited by this paper

Source: OpenAlex (CC0)