Evaluating the implementation of intermittent versus continuous fetal heart rate monitoring on intrapartum care and early neonatal outcomes using causal mediational modeling

Frontiers in Drug Safety and Regulation · Published 2026-06-09 · DOI 10.3389/fdsfr.2026.1755487

Free full text

Authors (7)

Omkar Basnet, Rejina Gurung, Pratiksha Bhattarai, Merlind Maria Hofert, Sunil Mani Pokharel, Prajwal Paudel, Ashish K. C.

Abstract

IntroductionIntrapartum fetal heart rate (FHR) monitoring can detect fetal compromise and provide indications for early action. However, the effect of implementing intermittent vs. continuous FHR monitoring with Moyo remains unclear. In this study, we compare the effect of implementing intermittent vs. continuous FHR monitoring using Moyo on intrapartum care and neonatal outcomes.MethodsA prospective observational design was used to evaluate two different FHR monitoring methods in seven hospitals in Nepal, with intermittent monitoring as the control group and continuous monitoring as the intervention group. The durations from 1) first Moyo placement to abnormal FHR detection and 2) first abnormal FHR detection to childbirth were compared using generalized linear regression. The causal mediational method assessed the risk of non-crying neonates after birth and intrapartum stillbirth between the groups using the Mantel–Haenszel (M–H) homogeneity method, standardizing the risk for mediators and confounders.ResultsA total of 1,091 participants were enrolled during the control period and 8,687 during the intervention period. Compared to the control group, the intervention group was associated with a non-significant reduction in time from first Moyo placement to abnormal FHR monitoring [adj.β = −35·5 min; 95% confidence interval (CI) = −73·2 to 2·22] and a significant reduction in time from first abnormal FHR to delivery (adj.β = −66·5 min; 95% CI = −106·2 to −26·8). The incidence of non-crying neonates was higher in the control group (11·5% vs. 10·0%), with an adjusted risk reduction of 31% (M–H RR = 0·69; 95% CI = 0·55–0·87) in the intervention group. The incidence of intrapartum stillbirth was non-significantly higher in the control group (4.5 vs. 3.0/1,000 births), with an adjusted risk reduced by 35% (M–H RR = 0·65; 95% CI = 0·25–1·70) in the intervention group.ConclusionCompared with intermittent Moyo, the duration to detect abnormal FHR and the time from abnormal FHR to delivery were significantly reduced, with a 31% reduction in the risk of neonatal resuscitation with continuous Moyo. The implementation of continuous FHR monitoring with portal devices such as Moyo can reduce the time to action following the detection of abnormal fetal heart rates and decrease the burden of infants requiring neonatal resuscitation.Clinical Trial Registrationclinicaltrials.gov, identifier ISRCTN16741720.

Abstract from DOAJ. Public domain (CC0 1.0).

Read the article at the publisher →

Publication details

Year
2026

Citation

Basnet, O., Gurung, R., Bhattarai, P., et al. (2026). Evaluating the implementation of intermittent versus continuous fetal heart rate monitoring on intrapartum care and early neonatal outcomes using causal mediational modeling. Frontiers in Drug Safety and Regulation. https://doi.org/10.3389/fdsfr.2026.1755487

Related articles