Value of a radiomics model based on high-resolution large matrix target reconstruction images in predicting the invasiveness of lung adenocarcinoma with pure ground-glass nodules

BioMedical Engineering OnLine · Published 2026-05-13 · DOI 10.1186/s12938-026-01548-z

Free full text

Authors (12)

Jun Lv, Yufan Gao, Min Ren, Li Zhou, Jianhui Li, Hong Zhang, Xin Li, Ximing Li, Minghui Hua, Keyi Cui, Wenjiao Wang, Zhenchun Song

Abstract

Abstract Objective To evaluate the potential of computed tomography (CT) radiomics, based on high-resolution large matrix target reconstruction images, in predicting the invasiveness of lung adenocarcinoma in pure ground-glass nodules (pGGNs) with a diameter ≤ 1.5 cm. Methods The clinical and imaging data of 297 patients with pGGNs, confirmed by pathology, were collected between March 2021 and June 2024. Pathological diagnoses included atypical adenomatous hyperplasia (AAH), adenocarcinoma in situ (AIS), minimally invasive adenocarcinoma (MIA) and invasive adenocarcinoma (IAC). The patients were divided into non-invasive (AAH and AIS) and invasive (MIA and IAC) groups based on pathology. Radiomics features were extracted using ITK-SNAP software, and a predictive model was built using Python 3.9.7, with feature selection based on least absolute shrinkage and selection operator regression. Receiver operating characteristic analysis, area under the curve (AUC), sensitivity, specificity and clinical decision curve analysis were used to assess model performance. Results Multivariate logistic regression revealed that the maximum lesion diameter, median CT value and solid component ratio were significant predictors of invasiveness (P < 0.05). The CT radiomics model achieved AUC values of 0.861 (95% confidence interval [CI] 0.811–0.912) in the training set and 0.790 (95% CI 0.687–0.892) in the validation set. A combined model integrating clinical and radiomics features showed improved predictive performance, with an AUC of 0.861 (95% CI 0.809–0.913) in the training set and 0.810 (95% CI 0.709–0.912) in the validation set. Conclusions The combined model based on CT radiomics and clinical imaging showed good performance in predicting the invasiveness of small pGGNs and may assist in clinical decision-making regarding follow-up management, surgery timing and treatment strategies. Further validation in prospective, multicentre studies is needed to verify these findings and assess generalisability to broader populations.

Abstract from DOAJ. Public domain (CC0 1.0).

Read the article at the publisher →

Publication details

Year
2026

Citation

Lv, J., Gao, Y., Ren, M., et al. (2026). Value of a radiomics model based on high-resolution large matrix target reconstruction images in predicting the invasiveness of lung adenocarcinoma with pure ground-glass nodules. BioMedical Engineering OnLine. https://doi.org/10.1186/s12938-026-01548-z

Related articles