Miri 4-points marker: a low-cost marking device for flanged intrascleral intraocular lens fixation with modified Yamane technique

BMC Ophthalmology · Published 2026-07-18 · DOI 10.1186/s12886-026-05134-8

Free full text

Authors (8)

Yong Zheng Wai, Lee Ling Chieng, Jun Fai Yap, Nurhayati Abdul Kadir, Gim Seah Chuah, Nurul Afzan Mustapha, Lik Thai Lim, Wai Seng Chiang

Abstract

Abstract Background Yamane’s flanged intrascleral intraocular lens (IOL) fixation is widely used in eyes without capsular support, but limitations in conventional conjunctival marking may affect surgical precision and consistency. This study compared the clinical outcomes of modified Yamane scleral-fixated IOL implantation using the Miri 4-Points Marker versus Castroviejo calipers, assessing visual outcomes and complications between these two approaches. Methods This retrospective cohort study at a single hospital of Malaysia included 44 eyes operated on between 2024 and 2025. Conjunctival markings were made using either the Miri 4-Points Marker or Castroviejo calipers. Two 30-gauge thin-walled needles created right-angled sclerotomies 2 mm posterior to the limbus. IOL haptics were externalized through the needles, cauterized to form a flange, and inserted into scleral tunnels. Descriptive statistics and binary logistic regression were used to assess factors associated with postoperative visual outcomes. Results Among 44 patients (mean age 64.4 ± 9.7 years, 77.3% male) who underwent intrascleral IOL fixation, the Miri 4-Points Marker was used in 72.7% of cases. Clinical outcomes with the Miri 4-Points Marker were comparable to Castroviejo calipers. Mean postoperative uncorrected visual acuity (UCVA) and corrected distant visual acuity (CDVA) were 0.7 (± 0.4) and 0.4 (± 0.3) logMAR, respectively. At one month postoperatively, 17.2% achieved good UCVA, increasing to 30.8% after excluding ocular comorbidities; 41.4% achieved good CDVA, rising to 46.2% without ocular comorbidities. On univariable analysis, high corneal astigmatism (> 2.5 D) was associated with poorer UCVA across all patients, regardless of Miri 4-Points Marker use (OR = 0.07, 95% CI: 0.01, 0.78, p = 0.03). Multivariable analysis did not identify any independent predictors. Conclusions The Miri 4-Points Marker is a feasible and safe adjunct for conjunctival marking in Yamane intrascleral IOL fixation. Observed short-term outcomes were similar to caliper-based marking, although this study’s chronological design precludes any conclusion of equivalence.

Abstract from DOAJ. Public domain (CC0 1.0).

Read the article at the publisher →

Publication details

Year
2026

Citation

Wai, Y., Chieng, L., Yap, J., et al. (2026). Miri 4-points marker: a low-cost marking device for flanged intrascleral intraocular lens fixation with modified Yamane technique. BMC Ophthalmology. https://doi.org/10.1186/s12886-026-05134-8

Related articles